Cleveland Range Floor Type Gas Convection Steamer 24CGA10.2 User Manual

Page 22

Advertising
background image

PROBLEM:

24CGA6, 24CGA10.2

Electronic timer displays "PAUS" and won't count down

START

Is steam heating

the cooking

cabinetabove 192

degrees (the set

temp of the

thermo-switch)?

Does the timer

count down when

the thermo-switch

is bypassed?

Yes

See

Steamer

won't steam

No

Replace the

electronic timer

No

Replace the

thermo-switch

Yes

PROBLEM:

24CGA6, 24CGA10.2

Steam leaks around the door.

START

Is COLD water
supplied to the

steamer?

Supply cold

water (35-60

PSI) to the

steamer.

No

Is the door gasket

physically

damaged?

Yes

Turn over the

gasket or

replace it.

Yes

Is the door out of

alignment?

No

Replace the

door bearings

and pins.

Yes

Is the drain

obstructed?

No

Remove the

obstruction

Yes

Is there 120 VAC

across the coil of

the condensate

solenoid?

No

Replace the
wiring to the

condensate

solenoid.

No

Is the solenoid

opening?

Yes

Replace the

condensate

solenoid.

No

Replace the

condensate spray

nozzle

Yes

Advertising