Stardance Direct Vent/Natural Vent Gas Heater

20012734

Install the Optional Fan

If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. If you are not installing a
Fan Kit, go to Page 16, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheo-

stat Assembly, connected by a cable. (Fig. 14) The
Blower Assembly mounts to the bottom rear of the
stove, and the Rheostat mounts to the valve bracket
to the left of the valve. The assembly includes a
‘snapstat’ which automatically turns the fan On (or
Off) above (or below) approximately 109˚. The Rheo-
stat also provides a range of fan speed settings from
Off (which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm
the fan spins freely.

WARNING

This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.

4. The rheostat control switch attaches to the left side

of the valve bracket at the front of the stove. (Fig. 17)

Remove retaining nut from shaft of rheostat. (if
preinstalled)

Insert the rheostat through the hole in the back
of the left side of the valve bracket, aligning the
locator pin with the smaller hole in that bracket.

Thread the retaining nut onto the shaft of the
rheostat, tightening with a wrench. Do not over-
tighten.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat
wire harnesses together.

ST473

Fan parts

#2767 FK26

9/29/00

Not Used on RF Models

Not Used on

Stardance

Snapstat Bracket

Snapstat/

Extension

Assembly

Rheostat

Assembly

Not Used

on RF

Models

Connect to PC Board on

RF Models Only

Blower

Assembly

ST473

Fig. 14 Fan kit components.

2. Remove the rear skirt insert panel at the bottom of

the Rear Skirt (Fig. 15) and fasten the blower assem-
bly to the firebox back with the two Phillips pan-head
bolts originally installed in the firebox back. (‘1’, Fig.
16)

NOTE: Steps 3 and 4 do not apply when the RF

valve is used. After attaching blower assembly to the
firebox, run the spliced female leads to the front of
the stove and attach to back of RF valve. (Page 34,
Fig. 58)

3. Attach the snapstat assembly to the snapstat bracket

with two sheet-metal screws. (‘2’, Fig. 16) Attach the
snapstat bracket to the stove with a hex-head bolt
passing through the bracket and into the stove base.
(‘3’, Fig. 16)

ST313

fk26

install fan kit

rear skirt insert

1/24/00

Rear Skirt

Sheet Metal

Screws

Rear Skirt

Insert

ST313

Fig. 15 Remove rear skirt insert.

ST314

Fk26ce

attach fan

1/24/00

Star Washer

Sheet Metal Screws

Phillips

Pan Head

Bolts

Star

Washer

NOTE: Shown

without shell for

clarification

Snapstat

Bracket

Snapstat

1/4” - 20

Hex Bolt

3

2

1

ST314

Fig. 16 Attach the fan assembly and the snapstat.

ST347a

JUV

FK28

rheostat install

9/21/00

Rheostat Retaining
Collar

Rheostat Knob

ST347a

Fig. 17 Attach the fan rheostat.