Stardance direct vent/natural vent gas heater, Side wall termination assembly, Install vent adapter pipe – Vermont Casting SDDVT User Manual

Page 17

Advertising
background image

17

Stardance Direct Vent/Natural Vent Gas Heater

20012734

ST355b

dura vent

attach inner assy

no restrictor plate

6/07 djt

CEMENT

1/4-20 x
3/8 Phillips
Screws

Inner Adapter

Pipe

ST355b

Fig. 21 Simpson Dura-Vent - install inner adapter pipe.

ST356

dura vent

attach outer assy

4/7/00 djt

ST356a

Fig. 22 Simpson Dura-Vent - install outer adapter pipe.

Side Wall Termination Assembly

1. Locate the vent opening on the wall. Refer to Page

7, Figure 6, to determine the opening centerline.
It may be necessary to first position the stove and
measure to find the hole location. Depending on
whether the wall is made of combustible materials,
cut the opening to the size shown in Figure 24. Com-
bustible wall openings must be framed as shown in
Figure 23.

VO584-100

Vent Opening

2/99 djt

CFM System

9³⁄₈”

(240mm)

9³⁄₈”

(240mm)

Combustible Wall

Framing Detail

DuraVent
System

10”

(254 mm)

7¹⁄₂”

(191 mm)

Noncombustible Wall

VO584-100

Fig. 23 Locate vent opening.

Install Vent Adapter Pipe

(Selkirk Corporation Vent Components)
The appliance adapter (AA) adapts DIRECT-TEMP to
most direct vent appliances incorporating outlet col-
lars configured to receive most common 4” (ID) by 6⁵⁄₈”
(OD) or 5” (ID) by 8” (OD) “Twist Lock” style, direct vent
systems.
The adapter incorporates two indentations on the outer
wall of the inlet end, which are designed to “Twist Lock”
into place upon attachment to the appliance outlet. Align
the adapter indentations with the entry slots of the appli-
ance outlet and slide together. Turn the adapter clock-
wise approximately one-quarter turn to lock in place.
The outlet end of the adapter is standard DIRECT-
TEMP construction.
For connection of Direct-Temp to units with 4” x 7” flue
outlets, the following methods have been approved:

Install the Universal/Napoleon Appliance Adapter
4DT-AAN.

Connect a standard Direct-Temp pipe length (do
not use an adjustable length in this application) a
minimum of 1¹⁄₂” over the flue outlet. The outside of
the Direct-Temp Length will fit inside the flue outlet

Secure with a minimum of two #8 x 1/4” sheet metal
screws and seal with hi-temp silicone.

For units factory equipped with appliance adapters from
other brands of Direct Vent systems, it is permissible
to simply slide a length of DT pipe over the appliance
adapter. Secure with a minimum of two #8 x 1/4” sheet
metal screws and seal with hi-temp silicone.

2. Measure the wall thickness and cut the wall sleeve

sections to proper length (MAXIMUM 12”). Assemble
the sleeve with the #8 sheet metal screws supplied.
Attach the firestop plate to the sleeve end with the
holes. (Fig. 24) NOTE: The wall sleeve is required
in combustible walls only.

3. Install the Wall Firestop/Sleeve assembly into the

wall cutout and fasten the firestop to the wall cutout
framing members. (Fig. 24)

For DuraVent pipe only: Install vent pipe by aligning

the locking system together, sliding the pipes togeth-
er and twisting clockwise.

• Install 90° elbow. Twist lock as before.
• Slide the wall plate over horizontal run before at-

taching the horizontal run to the elbow. Fasten wall
plate to wall.

4. For CFM Vent Pipe only: If necessary, measure

to determine the vertical length (X) of pipe required
from the adapter pipe to the wall cutout centerline,