Stardance direct vent/natural vent gas heater – Vermont Casting SDDVT User Manual

Page 18

Advertising
background image

18

Stardance Direct Vent/Natural Vent Gas Heater

20012734

including a 2” overlap at the joint. (Fig. 25) use a
hacksaw or tin snips to trim the pipe as needed.

5. Install first the inner then the outer straight pipe

section(s), trimmed end down, to the point of the el-
bow. Drill 3 holes through each joint and fasten with
sheet metal screws.

ZCS103

Zero Clearance Sleeve

& Firestop

12/6/99 djt

12”

(305 mm)

Max. Length

Sleeve

#8 Sheet

Metal Screws

Firestop

ZCS103

Fig. 24 Assemble the wall sleeve and firestop.

ST214a

measure vertical vent

12/6/99 djt

X

ST214a

Fig. 25 Determine the vertical pipe length.

sheet metal screws. Slide the trim collar up against
the wall plate to cover the screws. (Fig. 27)

10. For both CFM and DuraVent Systems: Install

the vent terminal. (Fig. 28) Apply high temperature
sealant one inch from the ends of the inner and outer
collars. Guide the inner and outer vent termination
collars into the adjacent pipes. Double check that
the vent pipes overlap the collars by 2”. Fasten the
termination to the wall with the screws provided, and
caulk the joint with weatherproof sealant.

11. For CFM only: Install Charcoal Gray Pipe Rings

(#7FSDRG) or Polished Brass Pipe Rings (#7FS-
DRP) at pipe joints, if desired.

ST215

measure thru wall

12/6/99 djt

X

ST215

Fig. 26 Measure the horizontal length.

ST216

install pipe thru wall

12/6/99 djt

Wall

Sleeve

Trim Collar

Wall Plate

ST216

Fig. 27 Install the horizontal pipe and wall plate parts.

6. Seal and install the elbow using 3 sheet metal

screws at each joint.

7. Measure, and cut if needed, the appropriate length of

pipe section needed to make the connection through
the wall. Include a 2” overlap; i.e. from the elbow
to the outside wall face, about 2” or the distance
required if installing a second 90° elbow. (Fig. 26)

8. Slip the wall plate and trim collar over the interior end

of the horizontal pipe and install into the wall sleeve.
Seal the joint inside the wall plate if needed to keep
cold air from being drawn into the home.

9. Seal the ends and connect the horizontal pipe to the

elbow. Fasten the wall plate to the pipe with three

ST217

install wall terminal

12/6/99 djt

Seal Both Ter-

minal Ends

Caulk Plate Joint with

Weatherproof Sealant

ST217

Fig. 28 Install the vent terminal.