Before Calling Service Personnel

Check the following points once again.

Installation

Power is not supplied.

• Check that power cord plug is properly connected to an AC outlet.

E.E pictures do not appear.

• Check the connection of this unit to TV and video camera.
• Check for defective cable.

Function/Operation

No operation with button pressed.

• Check if the video cassette is loaded correctly.
• Check if REC LOCK/RESTART switch is "OFF".
• Check for blinking of Dew lamp.

Dew lamp is blinking.

• The unit does not operate because a safety device is actuated. Wait

until the lamp goes out.

Date and time display data are not memorised,
in case of power failure.

• Check if the power cord plug of this unit is disconnected from the

outlet for a tong period of time.
Connect the power cord plug of this unit to an AC outlet to charge it
for at least 20 hours consecutively.

Recording

Playback, fast forward and rewind are possible,
but recording is not possible.
Recording is discontinued.

• Check that the video cassette safety tab is not broken.
• Check if video cassette tape is at the end.
• Check if more than 10 minutes has passed after pressing PAUSE

button during recording.

Power failure is over, but recording is not
resumed.

• Check if the REC LOCK/RESTART swlch is "OFF".
• Check that power failure period exceeds 7 days.

Repeat recording is not possible.

• Check that REPEAT switch is "ON".
• Check if

1

ALARM 1 is disoiaved.

• Check if STOP button was pressed during auto rewind mode.

Buzzer does not sound.

• Check if the BUZZER switch is "OFF".

Timer recording is not possible.

• Check if the present time is correct.
• Check if the Timer is programmed correctly.
• Check if the TIMER button is pressed.
• After timer recording time setting:

• Power failure took place?
• Power switch turned "OFF"?
• Power cord plug disconnected?

Alarm recording is not possible.

♦ Check that alarm sensor is correctly connected to ALARM IN

terminal.

• Check if alarm reset input and ground terminal is inadvertently

connected.

Playback

Pictures played back include noise.

• Adjust by Tracking Control.

• Clogging, deterioration or life of video head is exceeded.

Pictures played back flicker {snow}.

• Check for dirt on the video head.

Date and time are not displayed in the pictures

recorded tape.

♦ Check if the OSD switch was "OFF" in recording mode.

When the power cord of the recorder is
plugged in the outlet, recording begins but
playback operation is not possible.

• Check if the REC LOCK/RESTART s\N\tch is "ON".