DeviceMaster UP Modbus/TCP Quick Start: 2000477 Rev. G

Overview - 7

Overview

Modbus/TCP Installation Overview

The DeviceMaster UP follows these installation steps.

Note: The

BLUE

CAPITALIZED

links jump to external documents, which work while viewing from the ftp site or

from the CD.

1.

C

ONNECT

THE

D

EVICE

M

ASTER

UP

to the network.

2.

I

NSTALL

P

ORT

V

ISION

DX

from the CD or download and install the latest version.

3.

C

ONFIGURE

THE

D

EVICE

M

ASTER

UP

network settings using PortVision DX.

4.

Depending on the DeviceMaster UP model, do the following:

Models without Modbus/TCP loaded, you must install the software assembly (.msi) from the CD or
download and install the latest file, which contains the Modbus/TCP firmware and supporting files
required for Step 5.

Models with Modbus/TCP loaded on the DeviceMaster UP, you should check to see if a later version of
Modbus/TCP is available for installation. Check the Modbus/TCP version in PortVision DX against the
web site to see if a later version is available. Typically, you should download and install the latest .msi
file and upload the latest version, which may include updates or enhancements.

Note: Models that have Modbus/TCP loaded on the DeviceMaster UP are identified in PortVision DX and

the DeviceMaster UP is labeled accordingly.

5.

I

F

NECESSARY

,

UPLOAD

the Modbus/TCP firmware into the DeviceMaster UP using PortVision DX.

6.

Configure serial or Ethernet TCP/IP characteristics using the DeviceMaster UP embedded web page
(Server Configuration).

Modbus/RTU serial slave devices (

Page 10

)

Modbus/ASCII serial slave devices (

Page 12

)

Modbus/RTU serial master (

Page 14

)

Modbus/ASCII serial master (

Page 16

)

Read-only raw/ASCII serial devices (

Page 19

)

Read-only raw/ASCII Ethernet devices (

Page 26

)

Read/write raw/ASCII serial devices (

Page 36

)

Read/write raw/ASCII Ethernet devices (

Page 47

)

7.

Optionally, the DeviceMaster UPModbus/TCP User Guide provides detailed information about each web
page.

8.

You may want to reference the

P

ROGRAMMING

I

NTERFACE

chapter in the DeviceMaster UP Modbus/TCP

User Guide.

9.

Optionally, reference the

EXAMPLE

PLC

PROGRAMS

in the DeviceMaster UP Modbus/TCP User Guide.

10.

C

ONNECT

any serial device or devices.

11. Verify any Ethernet TCP/IP devices are connected to the same subnet as the DeviceMaster UP.