DeviceMaster UP EtherNet/IP Quick Start: 2000478 Rev. D

Filtering/Data Extraction Configuration - 65

Filtering/Data Extraction Configuration

Application Filtering/Data Extraction

Use the following procedure to configure application filtering/data extraction. Under the Filtering/Data
Extraction Configuration
section corresponding to the desired serial or socket port:

1.

Set To Application Filter Mode to the desired mode.

For String (128 char max): set the Filter Age Time to how long after the last read you want an entry
to be filtered.

For RFID (EPCglobal formats):

-

Set any or all of the To Application Filter Options (RFID Only) filtering options.

-

Set any or all of the To Application Filter Options (RFID/Barcode) filtering options.

Note: You must select at least one filtering option for filtering/data extraction to function.

2.

If Antenna Grouping is desired, set RFID Antenna Grouping option to reflect your antenna configuration.

Set the RFID Reader Interface Type to that of your RFID Reader configuration. If your RFID Reader is
not listed, please refer to the

Filtering and Data Extraction Reference Manual

for the supported RFID

reader interfaces. If your RFID reader format matches one the listed formats, then set the RFID Reader
Interface Type
to that format.

Set the Filter Age Time to how long after the last read you want an entry to be filtered.

If you want the DeviceMaster UP to discard any non-RFID tag messages, set the Discard Unrecognized
Data
to either To-Application or To-PLC/Application.

Refer to the

Filtering and Data Extraction Reference Manual

for formatting and other information.

To Application RFID Data Format

When the application interface is operating in RFID filtering mode, all data sent to the application will be
in the following format:

Note: The RFID parameters will be sent to the application in big-endian format. All parameters, with the

exception of the Tag data string, will have to be byte-swapped for use on a little-endian system.

Field

Data Type

Description

Company Code

DWORD[2]

Company Code extracted from tag data. Depending on
encoding scheme, this field may include Company Prefixes,
Company Prefix Indexes, or Government Managed Identifier.

Product/Location
Code

DWORD[2]

Product Code extracted from tag data

Depending on encoding scheme, this field may include the Item
reference, location reference, asset reference, object class, or be
set to zero.

Serial Number

DWORD[2]

Serial Number extracted from tag data.

Depending on the encoding scheme, this field may include the
Serial Number or individual asset reference.

Encoding Scheme UINT

Encoding Scheme from tag data

Filtering Value

UINT

Filtering value from tag data

Antenna Number UINT

Antenna number on RFID Reader/Scanner

Tag Data Length

UINT

Length of RFID tag string in bytes