Hardware Operating Conditions

21

VS3000 Specifications

Hardware Operating Conditions

The following table illustrates InterChangeVS 3000 operating
conditions.

Hardware Specifications

The following table illustrates the specifications.

Table 4. VS3000 Operating Conditions

Condition

Value

Heat output

36.8

BTU/Hr

Air temperature:

System on
System off

0 to 40

o

C

-20 to 85

o

C

Altitude

0 to 10,000 feet

Mean Time between Failures

9.7 years

Humidity (non-condensing):

System on
System off

8% to 80%

20% to 80%

Table 5. VS3000 Specifications

Topic

Specification

ISDN lines/VS3000

From 1 to 4

Baud Rate

Up to

512 Kbps

Line Voltage

100 - 240 VAC

Current Consumption

90 mA (at 120 VAC)

Power Consumption

10.8 W

Ethernet Host Interface

10Base-T or AUI

Dimensions (without feet)

16.75” x 11” x 1.75” (without brackets)

Weight

5 lbs