Speed – Casablanca Fan Company Casablanca Ceiling Fan 6643050 User Manual

Page 7

Advertising
background image

7

Pull-chain switches on the fan control the fan and lights.
Using the fan control pull-chain switch: Fan off at start.
First pull: fan ON, High speed
Second pull: Medium speed
Third pull: Medium Low speed
Fourth pull: Low speed
Fifth pull: Fan OFF
Using the optional light pull-chain switch: Light off at
start.
First pull: light ON
Second pull: light OFF
Direction of blade rotation is controlled by the reverse slide
switch on the side of the switch housing.
No changes in household wiring are required.

COLLAR

SWITCH

HOUSING

1. Refer to light kit instructions to assemble and attach your light

kit correctly.

2. Remove the two 8-32 screws from the switch housing cap.
3. Remove the plug from switch housing.
4. Install pull-chain switch and fi nger tighten collar on switch.
5. Connect one wire from pull-chain switch to the BLUE D1-Option

wire. Secure splice with a wire nut.

6. Connect other wire from pull-chain switch to BLACK wire from light

kit. Secure splice with a wire nut.

7. Connect WHITE wire from switch housing to WHITE wire from light

kit. Secure splice with a wire nut.

8. At the canopy, connect the BLACK and BLUE wires.

The W-41 wall control provides four-speed control of fan from a convenient wall location.
The W-41 is designed to replace a standard wall switch and will fi t wall boxes with a depth
of 2” or greater. Not for use with single pull-chain fan/light option wiring.
To install a W-41 wall control in place of an existing wall switch, follow the instructions
on the W-41 package.
Note: No rewiring is required if the fan is replacing an existing light fi xture.
Operation of the fan from the wall switch is simple:
1. Turn knob to obtain desired speed setting.

R

The W-81 wall control provides separate control of fan and light with two separate knobs
from a convenient wall location. The W-81 is designed to replace a standard wall switch
and wall boxes with a depth of 2” or greater. Requires two hot leads from wall box to ceil-
ing wiring box.
To install a W-81 wall control in place of an existing
wall switch, follow the instructions on the W-81 package.
Operation of the fan from the wall switch is simple:
1. Turn the upper knob to the desired fan speed.
2. Turn the lower knob to the desired light setting.

OFF

LO

MED

MED

HI

HI

OFF

MAX

CAUTION! Failure to set the pull-chain speed to HIGH can result in faulty operation of
the fan and damage to the W-41 wall control. To confi rm fan is set to HIGH: Turn W-41
fan speed switch to ‘HI’ - set fastest fan speed with pull chain.

CAUTION! Failure to set the pull-chain
speed to HIGH can result in faulty operation
of the fan and damage to the W-81 wall
control. To confi rm fan is set to HIGH: Turn
W-81 fan speed switch to ‘HI’ - set fastest
fan speed with pull chain.

NOTE: If a separate circuit is used to control the lights from a wall
control, the BLUE D1-Option wire in the canopy should be connected
to that switch leg with the BLACK fan power wire.

OPTIONAL LIGHT

PULL CHAIN

SWITCH

REVERSE

SWITCH

FAN & SPEED CON-

TROL

PULL CHAIN SWITCH

4-SPEED OPERATION

4-SPEED OPTIONAL WALL CONTROL • W-41

4-SPEED • OPTIONAL LIGHT FIXTURE INSTALLATION

4-SPEED • OPTIONAL WALL CONTROL • W-81

BLUE D-1

LIGHT FIXTURE

WHITE

BLACK

4-SPEED

Advertising