Cabletron Systems TRXI-24 User Manual

Page 14

Advertising
background image

REQUIREMENTS/SPECIFICATIONS

Page 2-3

Maximum Lobe Lengths

The lobe length is the physical length of the cable connecting a station
to its TCU port at the TRXI. Table 2-2 shows the maximum lobe
length, according to ring speed. The cable lengths listed in Table 2-2
are total lengths made up of UTP cable only.

Type 3 Media Filters

To connect a UTP lobe segment from a TRXI-22 or TRXI-24 to a
station supporting STP cabling, you need a Type 3 Media Filter.
Cabletron Systems offers the following Type 3 Media Filters:

TRMF

, RJ45 (UTP) connector to 10-inch DB9 (STP) cable with

LANVIEW

TRMF-2

, RJ45 (UTP) connector to DB9 (STP) connector

Maximum Number of Stations

When you use UTP lobe cabling anywhere on the ring, the number of
stations is limited to

100 stations

at ring speeds of either

4 or 16 Mbps.

Table 2-2. UTP Maximum Lobe Lengths

UTP Cable Type

Maximum Lobe Length

4 Mbps

16 Mbps

Category 3

100 meters

60 meters

(330 feet)

(198 feet)

Category 4

100 meters

60 meters

(330 feet)

(198 feet)

Category 5

130 meters

85 meters

(429 feet)

(280.5 feet)

Advertising