REQUIREMENTS/SPECIFICATIONS

Page 2-5

Maximum Lobe Lengths

The lobe length is the physical length of the cable connecting a station
to its TCU port at the TRXI. Table 2-4 shows the maximum lobe
length, according to ring speed. The cable lengths listed in Table 2-4
are total lengths made up of STP cable only.

Maximum Trunk Lengths

The maximum trunk cable length between the TRXI and another
active device is equal to the maximum drive distance as shown in
Table 2-5. When the neighboring token ring device is a passive device,
the combined length of twice the longest trunk cable plus the longest
lobe cable attached to the passive ring segment cannot exceed the
Maximum Drive Distance.

Maximum Number of Stations

When you use STP lobe cabling everywhere on the ring, the TRXI can
support up to

250 stations

at ring speeds of either 4 or 16 Mbps.

Table 2-4. STP Maximum Lobe Lengths

STP Cable Type

Ring Speed

4 Mbps

16 Mbps

IBM Types 1 & 2

200 meters

100 meters

(660 feet)

(330 feet)

IBM Types 6 & 9 (only
for station to wall jack
and patch panels)

30 meters

30 meters

(99 feet)

(99 feet)

Table 2-5. STP Maximum Drive Distance

STP Cable Type

Ring Speed

4 Mbps

16 Mbps

IBM Types 1 & 2

770 meters

346 meters

(2525 feet)

(1138 feet)

IBM Types 6 & 9

513 meters

230 meters

(1683 feet)

(755 feet)