Cabletron Systems TRXI-24 User Manual

Page 25

Advertising
background image

REQUIREMENTS/SPECIFICATIONS

Page 2-14

TPIM-F2

The TPIM-F2 shown in Figure 2-6 is an ST connector that supports
Multimode fiber Optic cabling.

Figure 2-6. The TPIM-F2

Note

: The transmitter power levels and receive sensitivity levels given

are Peak Power Levels after optical overshoot. A Peak Power Meter must
be used to correctly compare the values given to those measured on any
particular port. If Power Levels are being measured with an Average
Power Meter, then 3 dBm must be added to the measurement to correctly
compare those measured values to the values listed (i.e. -30.5 dBm
peak=-33.5 dBm average).

Parameter

Typical

Worst

Worst Case Typical

Value

Case

Budget

Budget

Receive
Sensitivity:

-30.5 dBm -28.0 dBm

Peak Input
Power:

-7.6 dBm

-8.2 dBm

Transmitter Power

50/125

µ

m

fiber:

-13.0 dBm -15.0 dBm 13.0 dB

17.5 dB

62.5/125

µ

m

fiber:

-10.0 dBm -12.0 dBm 16.0 dB

20.5 dB

100/140

µ

m

fiber:

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

Better than 10

-10

TPIM-F2

LNK

RX

TX

Advertising
This manual is related to the following products: