REQUIREMENTS/SPECIFICATIONS

Page 2-15

TPIM-F3

The TPIM-F3 shown in Figure 2-7 is an ST connector that supports
Single Mode fiber Optic cabling.

Figure 2-7. The TPIM-F3

Note

: Transmitter Power decreases as temperatures rise and increases

as temperatures fall. Use the Output Power Coefficient to calculate
increased or decreased power output for your operating environment.
For example, the typical power output at 25

°

C is -16.4 dBm. For a 4

°

C

temperature increase, multiply the typical coefficient
(-0.15 dBm) by four and add the result to typical output power
(4 x -0.15 dBm + -16.4 = -17.0).

TPIM-F3

LNK

RX

TX

Receive

Sensitivity

dBm

Less Power

More Power

-40

-35

-30

-25

-20

-15

-10

-5

0

Maximum

Receive

Input Power

Transmitter Power*

(At 25

°

C into

8.3/125

µ

m fiber)

Minimum Sensitivity (-30.0)

Typical Sensitivity (-31.0)

Maximum Sensitivity (-36.0)

Maximum Receive Input (-6.99)

Typical Receive Input (-7.5)

Minimum Receive Input (-9.72)

Maximum Transmit Power (-12.0)

Typical Transmit Power (-15.5)

Minimum Transmit Power (-21.0)

* Transmit Power Typical Power Minimum Power Maximum Power
Coefficient
(See Note Below)-0.15dBm/

°

C -0.12 dBm/

°

C-0.18 dBm/

°

C