REQUIREMENTS/SPECIFICATIONS

Page 2-6

2.1.3

Mixed Cable Types

If you mix cable types in your installation, you must compensate for
the different cable attenuations. Type 6 and Type 9 cables can be run
for only 2/3 the distance of Type 1. This means:

10 meters (Type 1)

6.6 meters (Types 6, 9)

Example: Maximum Length for Mixed Cabling Installation

-

16 Mbps ring speed and 130 stations.

-

The building has 60 meters of Type 1 cable in the wall.

-

How much Type 6 cable is available to connect the repeater

TCU port to the patch panel and the station to the local
wall jack?

-

Type 6 can only go 2/3 the distance of Type 1.

Solution:

100 meters = maximum cable length if only Type 1 cable is used

[60 meters of Type 1] + [40 meters of Type 1] = max. length

[60 meters of Type 1] + [(.66) x (40 meters) of Type 6] = max. length

|
|

26.4 meters of Type 6 (for patch panel and wall jack
connections)