LOCAL MANAGEMENT

Page 5-2

5.1

MANAGEMENT TERMINAL REQUIREMENTS

To access TRXI Local Management, you need either:

a Digital Equipment Corporation VT series terminal

a VT type terminal running emulation programs for the Digital
Equipment Corporation VT series

an IBM or compatible PC running a VT series emulation
software package.

5.1.1

Attaching the Management Terminal

Cabletron supplies an RJ45 Cable Kit with the TRXI. This kit includes
a UTP console cable with RJ45 connectors on each end. It also
provides adapters for DB9 or DB25 connections. Refer to the RJ45
Cable Kit Instruction Sheet for adapter pinouts and additional
instructions.

To attach the management terminal to the TRXI’s COM 1 port:

1.

Attach the male RJ45 connector to the COM 1 port of the TRXI as
shown in Figure 5-1.

2.

Attach the female end (25-pin or 9-pin, as applicable) to the COM
port on the terminal.

Figure 5-1. Management Terminal Connection

MANAGEMENT TERMINAL

CONSOLE CABLE

COM 1 RJ45 PORT

COM PORT

TRXI-24

TOKEN RING HUB

WITH

LANVIEW®