3 modem cable configuration and setup – Cabletron Systems TRXI-24 User Manual

Page 58

Advertising
background image

LOCAL MANAGEMENT

Page 5-4

5.1.3

Modem Cable Configuration and Setup

To access Local Management from a modem, use an RS-232 cable
available from Cabletron Systems. This cable connects the modem to
the TRXI COM 2 port. Figure 5-2 shows the pinout for a cable with an
RJ45 connector at the TRXI end of the cable.

Figure 5-2. Modem Cable Pinouts

To access Local Management, proceed as follows:

1.

Turn the modem on. The modem must be set for Auto Answer and
Data Carrier Detect must be active. Refer to your modem’s user
manual for operating instructions.

2.

Call the modem. The TRXI Password screen appears when you
establish a connection.

RJ45 COM 2

Port

Pin 1

RJ45 COM 2 PORT

1

4

5

2

3

7

TRANSMIT

RECEIVE

RECEIVE

TRANSMIT

SIGNAL GROUND

SIGNAL GROUND

RJ45 TO 25-PIN

C A B L E

25-Pin Female

"D" Shell Connector

RING

6

8

2

RING

20

DATA TERMINAL READY

DATA CARRIER DETECT

DATA CARRIER DETECT

2

8

DATA TERMINAL READY

Advertising