33 operating mode 81: speed setpoint frequency, n2, 7 parameterisation of the operating modes – ebm-papst ECI-63.XX-K4 User Manual

Page 69

Advertising
background image

69

7 Parameterisation of the Operating Modes

7.33 Operating mode 81: Speed setpoint frequency, N2

NOTe

In order for the parameter to function, KP_H must be > 0.

Function IN 1:

Input for frequency signal.

Function IN 2:

Selection of the speed setpoint source frequency / parameter N2.

Speed

Current limit

IN A

IN B

IN 1

IN 2

Direction

Value

Type

Value

Function

Comment

0

0

x

x

-

0

-

-

Free-wheeling

No current feed

1

0

Frequency

0

pos

Frequency

S

P

N control

1

0

Frequency

0

pos

Frequency

S

P

N control

1

0

Frequency

1

pos

N2

S

P

N control

1

0

Frequency

1

pos

N2

S

P

N control

0

1

Frequency

0

neg

Frequency

S

P

N control

0

1

Frequency

0

neg

Frequency

S

P

N control

0

1

Frequency

1

neg

N2

S

P

N control

0

1

Frequency

1

neg

N2

S

P

N control

1

1

Frequency

0

-

0

S

P

Stop

Stopping

1

1

Frequency

0

-

0

S

P

Stop

Stopping

1

1

Frequency

1

-

0

S

P

Stop

Stopping

1

1

Frequency

1

-

0

S

P

Stop

Stopping

NOTe

IN 2 = 0; brake closed
IN 2 = 1; brake open

Stop control =

If KP_H > 0; brake and stop in the current position on changeover to IN A = IN B = 1 + Coasting rh, lh.

If KP_H = 0; brake and stop on changeover to IN A = IN B = 1, run speed to 0.

S = Static
P = Parameter
F = Freeze
D = Dynamic
x = Arbitrary value

Advertising
This manual is related to the following products: