the zones on the screen indicates that this zone will be affected by DUCKER
function

o Activation threshold (TLK THRESHD): trigger threshold of the Talkover function.

The signal of the relevant input activates the Talkover function when it exceeds
this threshold. This trigger level depends on the sensitivity setting for the input on
the rear panel, but it is independent of the INPUT VOLUME adjustment made on
the device (only available in DUCKER mode, since in PAGER mode the function is
activated by pressing the PAGE button on the MPAGE4 console)

o Attenuation (DEPTH): attenuation applied by the function, when triggered, on the

rest of the signals sent to the affected zone)

o Attack Time (ATTACK): the time it takes the Talkover function to act from the

moment the signal exceeds the trigger threshold

o Hold Time (HOLD): time during which the Talkover function remains active, once

triggered and once the signal falls back under the trigger threshold (only available
in mode DUCKER, since in PAGER mode the function remains active as long as
the PAGE button is pressed on the MPAGE4 console)

o Release Time (RELEASE): time that it takes the Talkover function to stop

performing, progressively recovering previous levels of input signals for the
affected zone, after the Hold time

o Chime melody or "ding-dong" + playback volume: brief melody that plays when the

Talkover function is activated, in PAGER mode only (two melodies are available)

3. Adjustable parameters for the NOISE GATE function are:

o Activation

(ON/OFF)

o Activation Threshold (NG THRESHOLD). Defines the input signal level below

which the signal is attenuated with an amount indicated by DEPTH (closed gate)

o Attack Time (ATTACK). Determines the amount of time between the passing of the

threshold and the cancellation of the attenuation applied to the input signal (open
gate)

o Hold Time (HOLD): amount of time the gate stays open (without attenuation) once

the signal falls back below the detection threshold.

o Release Time (RELEASE). Determines the time it takes to close the gate again

after the hold time

4. The COPY FROM – PASTE TO operation copies all the settings from the source input to

the destination input, except for its name (LABEL)