Ecler DAM514 User Manual

Page 9

Advertising
background image

9

The special combinations of the setup keys are:

 Left and right MENU simultaneously for 2 seconds: access to the unit's SETUP menu (see

chapter 9)

 Left and right PARAM simultaneously for 2 seconds: access to the unit's front panel

locking/unlocking and password management (see chapter 10)

 SHIFT + left MENU (EXIT): return to the main screen, from any menu
 SHIFT + right MENU (CANCEL): undo the last parameter editing and recall the value as

before the change

 SHIFT + left PARAM (RECALL): load one of the presets (device setup) stored in the memory

 SHIFT + right PARAM (SAVE/ENTER):

o SAVE: save a preset (device setup) into memory
o ENTER: confirm a critical modification (e.g.: password change)

 Right MENU, kept pressed while powering up the unit: load preset #1, designed to be edited

and saved to be used as booting setup. This operation is allowed even when the unit's front
panel is locked with a password

 SHIFT hold down and maintained while powering up the unit: displays the "Power OFF to

recover factory defaults" message. After turning off and on again, default parameters (factory
defaults)
are restored, erasing all the user data, settings and presets in the unit's memory


SP/CLIP indicator light

The front panel LEDs indicates two types of information:

 Green light or SIGNAL PRESENT (SP): warn of the presence of signal at the mixer inputs.

These indicators illuminate when the input signal exceeds -40dBV.

 Orange light or CLIP: They light up when the signal is near the real clipping (saturation) level,

+12dBV. You must take care that these indicators do not remain continuously lit.

Advertising