EVCO EVB1256N9D User Manual

Page 49

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 49 of 92

PARAM.

MIN.

MAX.

M.U.

E

V

B

1

2

0

4

E

V

B

1

2

1

4

E

V

B

1

2

0

6

E

V

B

1

2

1

6

E

V

B

1

2

2

6

E

V

B

1

2

3

6

E

V

B

1

2

4

6

E

V

B

1

2

5

6

DEFROSTING

d0

0

99

h

8

8

8

8

8

8

8

8

if d8 = 0, 1 or 2, defrosting interval (13)

0

=

interval defrosting will never be activated

d8 = 3, maximum defrost interval

d1

0

2

- - - -

0

0

0

0

0

0

0

0

type of defrosting

0

=

ELECTRIC - during defrosting the compressor will

remain off and the defrosting output will be

activated; evaporator fan activity will depend on

parameter F2

1

=

BY HOT GAS - during defrosting the compressor

will be switched on and the defrosting output will

be activated; evaporator fan activity will depend

on parameter F2

2

=

VIA STOPPING OF COMPRESSOR - during

defrosting the compressor will remain switched off

and the defrosting output will remain deactivated;

evaporator fan activity will depend on parameter

F2

d2

-99

99.0

°C/°F

(1)

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

temperature at end of defrosting (only if P3 = 1); see also

d3

d3

0

99

min

30

30

30

30

30

30

30

30

if P3 = 0 o 2, defrosting duration

se P3 = 1, maximum defrosting duration; see also d2

0

=

defrosting will not be activated

Advertising