System configuration ~ g-ware screens, Copying and pasting settings, Safety mute – ClearOne comm XAPTM 800 User Manual

Page 34: Status bar

Advertising
background image

28

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

System Configuration

~ G-Ware Screens

Figure 3.17. Unit

shortcut menu

Figure 3.19.

Safety Mute

Figure 3.18. Inputs 1–8

shortcut menu

Copying and pasting settings

G-Ware has shortcut menus which appear when you right-click a selection or

program window in G-Ware. These shortcut menus provide quick access to options

such as Print, Copy, and Paste that pertain only to that selection or screen region.

Using the Copy and Paste commands, you can copy and paste unit data such as a

single setting or the entire unit’s settings depending on which window you are in. For

example, if you are in the Inputs 1–8 window, using the shortcut menu will allow you

to copy and paste all of the input settings to other inputs. You can also use keyboard

shortcuts (Ctrl+C and Ctrl+V) to copy and paste settings. If you want to apply all

settings of a selected input to the rest of the inputs, select Apply to All.

Safety Mute

The Safety Mute feature in G-Ware enables you to mute all outputs if feedback or

audio problems occur during the configuration process. To use Safety Mute, click the

Safety Mute button on the G-Ware toolbar. Then find and correct the cause of the

problem. Click the Safety Mute button again to unmute the outputs.

Status bar

There are two status lights at the bottom of the G-Ware window representing the

unit and the site. The lights illuminate in various colors to indicate current status.

Solid green. The item being configured is synchronized with the hardware.

Solid red. The information being configured is saved in the software offline.

Flashing red. The information is not saved or there is no hardware

connection.

Solid yellow. Communications are pending.

Flashing yellow. There is a communication error. In this instance, you should

disconnect from the unit and reconnect. The Message Log will indicate the error

that occurred. See page 75 for more information.