10

5 APPENDIX Ⅰ 24V AC WIRE GAUGE AND TRANSMISSION

DISTANCE RELATIONSHIP SHEET

The recommended max transmission distance is under the following environments: The wire

diameter is fixed and the DC 24V power voltage loss rate is below 10%. For the device of DC

power supplying, the max allowed voltage loss rate is 10%.

Please refer to the bold line (The second line) in the following sheet for 24V AC wire gauge and

transmission distance relationship.

0.8000

1.000

1.250

2.000

10

243 (74)

381 (116)

597 (181)

1529 (465)

12

204 (62)

316 (96)

495 (150)

1277 (387)

20

121 (37)

190 (58)

297 (90)

765 (232)

30

79 (24)

125 (38)

198 (60)

511 (155)

40

56 (18)

90 (29)

143 (45)

362 (110)

50

47 (14)

75 (22)

119 (36)

301 (91)

60

40 (12)

64 (19)

102 (31)

258 (78)

70

35 (10)

56 (17)

89 (27)

226 (68)

80

31 (9)

50 (15)

79 (24)

201 (61)

90

28 (8)

45 (13)

71 (21)

181 (55)

100

25 (7)

41 (12)

65 (19)

164 (49)

mm