Catalog number designation system – Chromalox PF455-3 User Manual

Page 7

Advertising
background image

O O O O - O O O - 0 0 H X 0 0 0 W - X 0 0 . 0 0 D - 0 0 0 V 0 0 P -

0 0 0 . 0 kW

000.0kW, (16kW/Ft.

2

MAX.)

Phase: 1P = Single Phase’ 3P = Three Phase

0 = Number of circuits

000V = Heater voltage (up thru 600V)

00.00 = Depth of heater frame in inches

(06.50 min. – 36.00 max.)

000W = Width of duct in inches (08 thru 120)

00H = Height of duct in inches (06 thru 40)

Terminal box construction and terminal box and frame material:
GPA = General purpose terminal box and all aluminized steel construction
GPP = General purpose terminal box and all painted steel construction
GPZ = General purpose terminal box and all plated steel construction
GPS = General purpose terminal box and all stainless steel construction
DPA = Drip proof terminal box and aluminized steel construction
DPP = Drip proof terminal box and painted steel construction
DPZ = Drip proof terminal box and plated steel construction
DPS = Drip proof terminal box and stainless steel construction

General style:
DHRI = Duct heater, remote controls, insert type
DHRF = Duct heater, remote controls, flanged type
DHII = Duct heater, integral controls, insert type
DHIF = Duct heater, integral controls, flanged type

0 M P - O O O O O - O O O 0 0 0 O O

Disconnecting Means:
ND = Nonfused disconnect switch (200A max.)
FD = Fused disconnect switch (48A max.)
TB = Terminal block (200A max.), disconnect switch by others

Control circuit voltage: 000 = 120, 208, 240, or 277V

Control circuit power supply:
T = Control circuit by integral transformer (120V Sec. Only)
R = Remote control circuit by customer (120, 208, 240, or 277V)

Fan interlock method:
AS = Air flow switch
FI = Fan interlock relay
FD = Fan interlock relay with fan delay

Heating element termination:
M = Threaded terminals with mica insulation
R = Threaded terminals with ceramic insulation (480V max.)
H = Hermetic seals (480V max.)

Method of attaching heating element to heater frame:
WA = Painted steel fin and sheath
GW = Mounting washer staked to element sheath with gasket
BF = Brass fitting with gasket
SS = Stainless steel fin and sheath

Sheath, fin, and finish of heating element:
PS = Painted steel fin and sheath
MO = Monel fin and sheath
SS = Stainless steel fin and sheath

Mounting position of heater:
1MP = See Figure 16 on page 4, mounting position 1
2MP = See Figure 16 on page 4, mounting position 2
3MP = See Figure 16 on page 4, mounting position 3
4MP = See Figure 16 on page 4, mounting position 4
5MP = See Figure 16 on page 4, mounting position 5
6MP = See Figure 16 on page 4, mounting position 6

-7-

CATALOG NUMBER DESIGNATION SYSTEM