Conversion to Natural Gas or to LPG

Injectors Replacement of Top Burners

Every cooker is provided with a set of injectors for the various types of gas.
Injectors not supplied can be obtained from the After-Sales Service.
Select the injectors to be replaced according to the table at page 47.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

To replace the injectors proceed as follows:
– Remove the pan supports, the burner caps and flame speaders.
– Using a wrench, substitute the nozzle injectors “J” (figs. 44 - 45) with those most suitable for the kind of

gas for which it is to be used (see “Table for the choice of the injectors”).

The burners are constructed in such a way so as not to require the regulation of the primary air.

J

J

Triple Ring
burner

Adjusting of the Minimum of the Top Burners

Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit
even with a quick turn from the maximum position to that of minimum.
The flame adjustment is done in the following way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw “F“ until adjustment is

correct (fig. 46).

Normally for LPG, tighten up the regulation screw.

Auxiliary,

Semi-Rapid

and Rapid

burners

F

Fig. 44