Table for the Choice of the Injectors

Cat: II 2H3+

Burners

Nominal

Power

kW

Reduced

Power

kW

G30 - 28-30 mbar

G31 - 37 mbar

G20 - 20 mbar

Ø Injector

1/100 mm

Ø Injector

1/100 mm

Auxiliary (A)

1,00

0,30

50

72 (X)

Semi-Rapid (SR)

1,75

0,45

65

97 (Z)

Rapid (R)

3,00

0,75

85

115 (Y)

Triple Ring (TR)

3,50

1,50

95

135 (T)

Increase of Air Necessary for Gas Combustion (2 m

3

/h x kW)

Burners

Air necessary for combustion (m

3

/h)

Auxiliary (A)

2,00

Semi-Rapid (SR)

3,50

Rapid (R)

6,00

Triple Ring (TR)

7,00

Lubrication of the Gas Taps

The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the
appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.