background image

Oven

Injector

INSTALLATION INSTRUCTIONS

26

Burner

Grill

150

110

NATURAL GAS (G20)

Kitchen Worktop Thickness

30mm

45mm
55mm

Worktop Thickness + 15mm

40mm

40mm +

Note: The hob may project up to the worktop thickness + 30mm

provided this is at least 100mm behind the front of the oven.

Maximum Hob Depth From Worktop

Surface Down

Heat Input

3.7 kW

2.5 kW

TECHNICAL DATA

Gas connection

Rp

1/2

(

1/2

" BSP female)

Gas supply

G20 at 20 mbar.

Pressure test point

Grill injector

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug.
230 - 240 a.c. 50H

Z

3A fuse

1. GENERAL

The appliance is designed for mounting at a safe level into an oven housing
which must be secured to the backing wall. The appliance can be installed in a
tall cabinet or alternatively under a worktop with or without a hob unit above.

It is important that the installation instructions for the hob are strictly observed.
Where a hob is fitted above the oven unit the electrical connection for the hob should be made
with an 85˚ C high temperature flexible cord to table 15 of BS 6141.
A gas hob fitted above the oven unit should be connected to the gas supply with rigid
tubing.