Installation, Ventilation, Final installation – Creda Single Oven User Manual

Page 27: List of loose items

Advertising
background image

2. VENTILATION

a. The oven housing unit cabinet dimensions must comply with fig. 3 or fig. 4.
b. An air gap of 30mm minimum must be provided at the rear of any top or bottom

cupboards or shelves (see fig. 1).

c.

It is necessary that the cabinets are provided with unobstructed ventilation,
i.e. from adjacent cabinetry. This can be done by either raising the base of the
cabinets using the adjusting feet (or spacers) or alternatively by providing a slot in
the cabinet plinth to the dimensions in fig. 1.

d. The air gap at rear allows the warmed air to pass out of the inner cabinet space.

Where it is intended to fit cupboards above the oven unit to ceiling height, it is
essential that the warmed air is exhausted through the front of the cabinet
(see fig. 1).

e. If an oven unit is installed adjacent to a tall cabinet, steam escaping from the

oven when the door is opened could condense on and maybe stain the
adjacent surface. To prevent permanent staining, the adjacent surface should
be made of a material that is heat resisting and easy to clean. Adjacent tall
cabinets should not be deeper than the oven housing cabinet.

3. FINAL INSTALLATION

a. Using a spirit level, check that the housing cabinet is level from side to side

and from front to back in its installed position.

b. Correct any unevenness by placing spacers under the bottom of the cabinet.

Make sure that the cabinet rests firmly on the floor without rocking.

c.

Before the oven is fitted, the cabinet must be firmly secured to the backing
wall for stability.

d. The oven unit should now be lifted (this is a two person lift) into the cabinet

and pushed fully home.

e. Finally, the oven is secured to the cabinet by means of the four Pozi Wash

Head screws - two through each side trim.

f.

Remove all packaging material from the grill and oven interior.

LIST OF LOOSE ITEMS

4 x Pozi Wash Head No. 6 x 15mm screws.

INSTALLATION

27

Note: This appliance must not be installed over any other appliance that

generates heat.

Advertising