Biopointe central user’s manual – Keri Systems BioPointe User Manual

Page 75

Advertising
background image

Biopointe Central User’s Manual

Appendix A 71

Table 4.6(e): Setup Mode Events (Trace Event)

Identifier
(hex)

Identifier

(dec)

Description

1

0xA0

160

Setup Mode Entered

2

0xA1

161

Setup Mode Exited

3

0xB1

177

A user’s fingerprint was changed

4

0xB2

178

A user was added

5

0xB3

179

A user was deleted

6

0xB4

180

A Master was added

7

0xB5

181

A Master was deleted

8

0xC0

192

Device date and time was changed

9

0xC1

193

Door Configuration was changed

10

0xC2

194

Alarm Configuration was changed

11

0xD0

208

A Card/PIN was changed

12

0xD1

209

Door secure – The door is configured to always locked.

13

0xD2

210

Door Unsecured – The door control was set to always unlocked.

14

0xD3

211

Door Normal – The door is configured to be “Disable” i.e. Door will
unlock upon successful verification.

Setup Mode Events record critical events that happen in the setup mode.

When accessing the setup mode, the event, [Setup Mode Entered] will be recorded. When the user
subsequently quits from the setup mode, the event, [Setup Mode Exited] will be recorded.

When the supervisor is in the setup mode, he may add or delete a user, change the date and time,
change the alarm configuration or change the door configuration. Each of these events (as listed in
the table above) will be recorded.

Table 4.6(f): Failed Attempts

Identifier
(hex)

Identifier

(dec)

Description

1

0xE7

231

Failed matching (for users registered with fingerprint)

2

0xE8

232

Failed matching (for users registered with card)

3

0xE9

233

Failed matching (for users registered with card/PIN)

4

0xEA

234

ID not found in device database

5

0xEB

235

Fingerprint match could not be found using partial search

6

0xEC

236

Matching was aborted

Failed Attempts logs comprise the events in the table above. Each event describes the reason for
the failure to achieve a successful authentication.