5 ATEX marking – meaning of icon

• The balances of the OEX series meet the requirements of group II,

class 2 for devices in as per Directive 94/9/EU and are marked as -

II 2 G IIC T4.


Icon declaration as per Directive 94/9/EG:















The balances of the OEX series are intended for indoor and outdoor use. However,
they should not be exposed to aggressive chemical vapours, critical temperatures
and high humidity. The platform balance construction is made of stainless steel.

Category for group II
devices:

1 – The device

guarantees a very
high safety level,

- for operation in
areas 0,1,2

2 – The device

guarantees a very
high safety level,

- for operation in
areas 1,2

3 – The device

guarantees a normal
safety level,

- for operation in
Area 2

Explosive atmosphere:

G – Caused by gas, steam

and mist.

D – Caused by dust

Icon for explosion
protection used

Construction
type:

o – Oil protection

p – Gas

protection
with
excessive
pressure

q – Sand

protection

d – Flameproof

protection

e – Reinforced

construction

ia – Intrinsically

safe
construction
for operation
in areas
0,1,2,

ib – Intrinsically

safe
construction
for operation
in areas 1,2,

Electrical
equipment –
compatible with
one or few types
of explosion
protection
constructions

Gas explosivity group -

Examples:

-IIA:

Propane (T1)

Benzene (T3)
Butane (T2)
Ethyl alcohol (T2)

-IIB:

Ethylene (T2)

-IIC:

Acetylene (T2)

Hydrogen (T1)

,

Temperature class – max
surface temperature of device
parts exposed to explosive
mixtures:

T1: 450

0

C

T2: 300

0

C

T3: 200

0

C

T4:

135

0

C

T5:

100

0

C

T6:

85

0

C

Temperature class

of gas and vapour
spontaneous ignition:

T1: > 450

0

C

T2: > 300

0

C

T3: > 200

0

C

T4:

> 135

0

C

T5:

> 100

0

C

T6:

> 85

0

C

Safety level

Gas atmosphere:

- Ga
- Gb
- Gc

Dust atmosphere:

- Da
- Db
- Dc

Doc.No.OEX-BA-e-1411