1 manual totalizing – KERN & SOHN IFS 300K-3 User Manual

Page 23

Advertising
background image

KFS-T-BA_IA-e-1213

23

7.7.1

Manual totalizing

With this function the individual weighing values are added into the summation

memory by pressing

and edited, when an optional printer is connected.

Menu setting:

F11 AC“  „5 AC 1“, see chap. 8

F7 UA“  „4 UA 5“ see chap. 8


Calculate the average item weight (see chap. 7.6.1) or enter it manually (see

chap. 7.6.2).

Place weighing goods A.

Currently placed weight

Selected item weight


Currently placed quantity of items

Wait for stability display, then press

. The displayed value (e.g. 50 pieces) will

be added to the summation memory and printed if an optional printer is

connected.

****************

NO: 1

GS: 5.0000kg

UW: 100g

PCS: 50pcs

****************

Remove the weighed good. More weighed goods can only be added when the

display ≤ zero.