Weighing with tolerance range

You can set an upper or lower limit when weighing with tolerance range and thus
ensure that the weighed load remains exactly within the set limits.
During tolerance controls such as dispensing, portioning or sorting the unit will
indicate whether a value exceeds or falls short of limits with an optical [ok] as well as
an audio signal according to the setting in the menu block “

“; see chapter

9.2.

Selectable mode

Description

bP 1

Acoustic signal turned off

bP 2

If load is within tolerance range, [ok] will be displayed
and audio signal will be sounded.

bP 3

If the load is beyond the tolerance range [ok] will be
shown and the audio signal will sound.


1. Call up menu

 In weighing mode press

und

at the same time

and the first menu block

will appear.

2. Set limit values

 Keep on pressing

until the display used for entering

the lower limit

SET LO

appears.

 Press

, the current setting will be displayed.

 Press the navigation buttons (see chap. 5.10.1) to enter the

lower limit value, the active digit is flashing.

(example)

 Confirm input by

.

 Select

SET HI

by pressing

.

Advertising