Before installing optional Remote Controls, determine the most convenient locations(s). When deciding
on the best location for the remote controls, please consider the following items:

1. Place the controls out of reach of small children.
2. Avoid locations where the control(s) will become hot, such as over a radiator, register, or other

heat sources.

3. Avoid direct sunlight. (The digital readout can be difficult to read in direct sunlight).
4. Avoid areas where the remote can be splashed with cooking water, oil, or sauce.
5. The remote control operates with low voltage, 12 volts DC.

Main or Optional Remote Control

°F

Set Temperature

Main Controller

239-44509-00

In Use

Priority

endless hot water system

CAUTION: Hotter water increases the risk
of scald injury. Before changing temperature
setting, see instruction manual.

Figure 44

Temperature Control(s) Installation (Optional):

1. The optional remote controls are intended to be installed in a bathroom close to a shower or tub.

The controls may be wired in series or parallel depending on the distance from the water heater
to the controls.

2. Mark the holes on the wall using the control mounting plate and drill two mounting holes using a

3/32” (2.4 mm) drill bit and a clearance hole for the cable using a ¼” (6.4 mm) drill bit.

3. Run the cable from the control to the water heater or another control, which ever is closer or more

convenient.

4. Remove the face plate from the remote control by inserting a screwdriver in the slot and twisting

open.

5. Connect the cable to the terminal screws of the remote control.

6. Mount the control to the wall using the holes drilled and with the screws supplied. Note: Plastic

wall anchors may be required if the control is not located over a stud when mounting on
wallboard.

Note: If the cable cannot be run inside the wall cavity, then the plastic knockout should be removed
from the top or bottom of the control to allow flush mounting with the wall.


7. Disconnect the power from the water heater and remove the front cover.