Warning – LAARS IGI-180C - Installation Manual User Manual

Page 55

Advertising
background image

55

FIRST AID FOR SCALDS

1. Remove all wet clothing quickly. Wet clothing retains the heat.
2. Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper

burning. Never use butter, oils, or ointment to cover the burn. They may retain the heat.

3. Use a blanket to keep the scalded person warm.
4. Seek medical advice.


ERROR MESSAGES ON REMOTE TEMPERATURE CONTROL DISPLAY

The Laars EVERHOT

® continuous flow water heaters have the ability to monitor and display

any operating faults on the control display. The error messages will display on the monitor and will assist
in servicing the water heater. The following is a listing of the error codes, which may flash on the monitor
in case of a malfunction with the water heater. Please quote the code displayed when calling for service.

Code

Displayed

Fault Remedy

10

Air supply or exhaust blockage

Check for a restriction in the exhaust

vent.

11

No Ignition

Check to make sure the gas supply is

on to the water heater.

12

Flame Failure, grounding failure

Make sure gas is turned on at the

water heater; check for obstructions in

exhaust vent.

14

Thermal Fuse

Heat exchanger overheated

16 Over

Temperature

Warning

Excessive temperatures, wrong dip

switch setting, incorrect manifold

pressure or gas type.

32

Outlet water temperature faulty

Outlet sensor or wiring may be

defective

33

Heat exchanger outlet water temperature faulty

H.E. outlet sensor or wiring may be

defective.

34

Combustion air sensor faulty

Thermistor or wiring faulty

52

Modulating Solenoid Valve signal abnormal

Check gas control and wiring

61

Combustion Fan Failure

Combustion fan or wiring faulty

71

Solenoid Valve Driving Circuit Faulty

Check all gas solenoids and wiring

72

Flame Sensing Device Faulty

Lack of flame sense – check flame rod

and wiring connections.

LC

(00)

Scale build-up in Heat Exchanger

(When checking maintenance code history, “00” is

substituted for “LC”).

Build up of lime scale in heat

exchanger – needs to be flushed.

If any of the above error codes are seen flashing on the remote display, call for service.

WARNING

Failure to remedy faults may result in severe burns, scalds, and/or death.

Advertising