Longshine GT150 User Manual

Page 56

Advertising
background image

48

EMB-M3 User`s Manual

Gate A20 Option

Select if chipset or keyboard controller should control GateA20.

Normal

A pin in the keyboard controller controls GateA20

Fast

Lets chipset control GateA20


Typematic Rate Setting

Keystrokes repeat at a rate determined by the keyboard controller.
When enabled, the typematic rate and typematic delay can be selected.

The choice: Enabled, Disabled.

Typematic Rate (Chars/Sec)

Sets the number of times a second to repeat a keystroke when you hold
the key down.

The choice: 6, 8, 10, 12, 15, 20, 24, 30.

Typematic Delay (Msec)

Sets the delay time after the key is held down before it begins to repeat
the keystroke.

The choice: 250, 500, 750, 1000.

Security Option

Select whether the password is required every time the system boots or
only when you enter setup.

System

The system will not boot and access to Setup will be
denied if the correct password is not entered at the
prompt.

Setup

The system will boot, but access to Setup will be
denied if the correct password is not entered at the
prompt.

Note: To disable security, select PASSWORD SETTING at Main
Menu and then you will be asked to enter password. Do not type
anything and just press <Enter>, it will disable security. Once the
security is disabled, the system will boot and you can enter Setup
freely.

Advertising