MCS-2 CONTROLLER

The left side of this controller is identical to the MCS-1 consult last page.

Page 6

8.) Reset

9.) Clear

10.) Clone RX

11.) Clone TX

12.) Clone/Learn LED

13.) OK LED

14.) Learn Button

15.) IR Sensor LED

16.) Numeric Entry
17.) Enter Button
18.) Macro Button
19.) Skip Backward
20.) Skip Forward
21.) Power On
22.) Reverse
23.) Forward
24.) Play
25.) Pause
26.) Stop

POWER

TAPE

DM2

AMFM

DM1

CD2

OK

CLONE/

LEARN

VOL

VOL

ERROR

IR SENSOR

LEARN

MUTE

CLONE TX

CLONE RX

PLAY

PWR

0

8

E

7

M

9

CD1

CLEAR

RESET

2

5

4

1

6

3

MCS-2

8.) Reset - This resets the local zone controller if an IR command “locks up” the zone. It will not erase the

local zone memory. It will just send a local clear command.

9.) Clear - This button has 3 modes: a.) Device mode - will clear learned commands from the local zone

memory. If you press clear and then say source selector #1 then the commands associated with that

page of memory will be erased. b.) Storage mode - this will allow any individual key to be erased and

reprogrammed. c.) Macro memory mode - this will allow you to reprogram a individual macro key (0 -9).

(This is a permanent erase function, so be careful with this command.)

10.) Clone RX - This button will place the controller into a “ready to receive commands” mode. This is the

learning mode. When setting up the system initially, place all but one controller in this mode and use the

one master controller to teach the local zones their commands. The clone/learn LED will light and stay

on. When the data is received correctly, the red LED will go out and the green OK light will go on. This

process takes between 6 and 8 minutes. *See detailed “clone” description on page 8.

11.) Clone TX - This button will place the controller into a “ready to transmit commands” mode. This is the

teaching mode. When setting up the system initially, place one controller in this mode and use it as a

master controller to teach the other local zones their commands. The clone/learn LED and OK LED will

stay on. When the data is transmitted correctly, the red LED will go out and the green OK light will flash

then go off. This process takes between 6 and 8 minutes. *See Page 8.

12.) Clone/Learn LED - This LED will let you know the status of transmit and receive during the learning

or teaching processes.

13.) OK - This LED will also let you know the progress of the learning/teaching processes. *See Page 8.

14) Learn Button - This button puts the controller into a learning mode.*See Page 8.

15.) IR Sensor - Use this IR window when teaching a controller new IR commands with an external

remote.

Advertising