The MCS-2 controller is designed to learn and store IR codes for virtually any piece of audio/video

equipment. This enables the individual programming and use of multiple functions for all of your source

components.

Programming Individual Functions

1) Press the “learn” button on the controller. The left, red “Clone/Learn” LED will begin flashing.

2) Press the source device button to be programmed.

3) Press the numeric or function key you wish to program on the right side of the controller. The red

“Clone/Learn” LED will stop flashing and glow continuously.

4) Hold the source remote control IR emitter 1” to 2” from the “IR Sensor” on the controller and press

the corresponding function key on the source remote. After a short period of time, the right, green “OK”

LED will glow indicating the acceptance of that command. At this point the controller will return to a

flashing red LED. It is now ready to be taught the next command for that source. (A solid red and green

LED simultaneously indicates an error with that command. Should this occur, clear it and try reentering

that function.)

5) Repeat steps 2-4 for the next desired function.

6) When all the desired functions for a particular source have been programmed, we suggest you “reset”

the keypad.

7) Repeat steps 1-6 for the remaining functions.

(All of the numeric and function keys will learn any ir code. Functions programmed into the controller

are solely at the discretion of the installer.)

Cloning

The MCS-2 has a cloning feature that will allow you to down load the information stored in one controller

to up to five additional controllers within an installation.
Once one of the controllers is programmed, go to the other controllers and press the “Clone RX” button.

Then return to the programmed controller and press the “Clone/TX” button. The green LED will remain

lit while the cloning process is in progress. When the process is complete, the green LED will turn off.

This should take about 8 minutes. It is a good idea to then “reset” all of the controllers.
Now all the controllers share identical information. The nonvolatile memory will remain regardless of

whether the controllers are plugged into the system. Using the “Clear” button will clear the controller

memory. To erase an entire page of memory, simply press the ”Clear” button and then a “Source Device”

button. By pressing a source device button, the “Clear” button and one of the programmed function

buttons will erase a single function. Once cleared, a controller or individual function can be reprogrammed.

NOTE:

It is important to avoid issuing any IR commands or allowing any external IR interference during the

cloning process. This will result in corrupted information being sent to the receiving controllers.

Should a controller’s programming be corrupted, it may be necessary to completely clear a controller

to factory condition. This is done by cloning an unprogrammed controller to the corrupted controller.

Once this is done, that controller can then be re-cloned.