ZONE CONTROLLERS

1 8

OUT

1 8

1 8

1 8

1 8

1 8

1 8

1 8

IN

1

2

3

4

5

6

MASTER

INDIVIDUAL ZONES

CONTROLLER SECTION

7.) Master Output - This connector allows the “party” mode to apply to multiple units if additional

units are added.

8.) Master Input - This is for the “party” mode controller. This controller should be located near the

unit and sources. It will override all zone controllers and select a source which will then play in all

zones. This mode is used for playing the same background music in all zones such as during a party.

The individual wall controllers still have the ability to select a different source after the party mode is

engaged. It uses a standard 8 pin RJ-45 connector.

9.) Individual Zone #1 Controller - This connector hooks up the wall controllers used in zone #1.

The signals from this wall controller control all the functions in zone #1. It uses a standard 8-pin

RJ-45 connector.

This connector is duplicated for the remaining 5 zones and function exactly the same.

PAGING/VOLTAGE CONTROL SECTION

10.) Audio Inputs - This is an audio sensing circuit and accepts the signal from an external phone

system, or a pre-amplified microphone (i.e.: a mixer output), that has the capability of sending a page

signal from the master phone unit. The signal from this phone system will mute whatever source is

playing in all zones and allow the person speaking to page into all zones simultaneously. When the

signal is disengaged, the music will return to the previous level. Even zones that are not currently

on will “open” and allow the announcement to be made. Inside the unit is a master DIP type switch

which allow the installer to turn off the paging and doorbell override. This is especially suited for a

nursery. Pin 1 is for signal and pin 2 is for ground.

11.) Switch Inputs - This input is designed for older systems like intercoms that require a push to

talk “latch” mode contact before the audio signal can pass through. This is a “hard” bypass of the

audio sources. This can act as a whole house mute as well.

12.) Doorbell A Input - This input takes the signal from the contact closers from the front doorbell

transformer. When engaged, the source signal mutes and a distinctive chime (on board) plays through

the speakers. It will even play through zone speakers that aren’t on unless locked out.

13.) Doorbell B Input - Same as above but with a separate distinctive chime sound so you can

differentiate between the doors.

14.) Control Voltage Output - This output sends a constant 5 volt D.C. signal out to trigger ancillary

equipment when the unit is powered up. When the unit goes into the “sleep” mode, this voltage stops.

15.) Control Voltage In - This allows an external sub system that sends a control voltage output to

this system to power up the unit from the “sleep” mode. This signal can be from 5 to 12 volts D.C.