A.3 Environmental

Temperature:

20°F to 130°F operating

0°F to 130°F storage


Humidity:

0-95% RH, Noncondensing


EMI/RFI:

Per FCC Part 15 Class A


A.4 Enclosure

Options:

Panel Mount Chassis

(7.7" wide 8.8" high x 4" deep)

Suitable for Wall or Panel Mounting

Battery Mounted Separately

Nema 4 Fiberglass Case with Hard Cover

(12” Wide, 15.5” High, 6.6” Deep)

Nema 12 Fiberglass Case with Hard Cover

Nema 12 Fiberglass Case with Clear Cover

(9” Wide, 10.5”High, 6.5” Deep)


Weight:

Panel Mount Unit 4 lbs

Nema 12 case: 6 lbs

Full system: 10 lbs


A.5 Speech

Type:

Nonvolatile, better-than-telecom quality, with
Automatic Gain Control of user-recorded messages.


Resident vocabulary for programming prompts, and
User-Recorded Messages for System Greeting and
each Fault Input.


Recordable Message Lengths: 10 Seconds System Message

6 Seconds Each Fault Message


A.6 Fault Inputs

Type:

Isolated Dry Contact, Normal Open or Normal
Closed, Non-Latched, optional Alarm-Clear.

Sensing

frequency:

1

Hz


Sensing current:

Closed circuit sees a 10 mA (nominal),
10 millisecond-duration pulse, once every second.