9. Attach hose H02 to port “B” on the 3

rd

station of the block. Route the free end of the

hose (H02) to the John Deere main lift tee, which is located on the right hand end of the
John Deere valve block (Figure 27).

Figure 27: Main Lift Tee Location

10. Disconnect the John Deere main lift tee and insert the supplied 6FORXR 6MORT tee fitting

(*F03). Attach the hose (H02) to the 6FORXR 6MORT tee fitting (*F03).

Figure 28: Main Lift Tee Fitting Installed

You must ensure no hydraulic components will interfere with any sprayer

parts or be pulled tight at any time.

Main Lift Tee

F03

H03