5

Mount Cabinet

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than 1 disconnect switch.

!

WARNING

UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage.
Cabinets will support a maximum weight of 400 lbs/181 kg

when installed beneath a vertical furnace or air--handling

unit. When setting furnace on cabinet, do not drop it into

place. Position the furnace correctly on the cabinet to prevent

a corner from slipping down and damaging the cabinet or its

components.

CAUTION

!

a. Turn off power to the heating and cooling system.

b. Remove the existing furnace filter and discard. Excessive

system static may result if the Infinity Air Purifier is used
with other filtration devices.

c. Remove the air purifier cartridge and enhancement module

from the Infinity Air Purifier cabinet.

d. Position the cabinet between the furnace and return air duct

(see Figures 3, 4, 5 and 6). A transition duct may be re-
quired.

e. Furnace adapters have been included for installer conve-

nience. They are designed for top or bottom mount installa-

tions (see Fig. 6).

Furnace
Adapters

Airflow

Airflow

A05274

Fig. 6 -- Use of Furnace Adapters

f. Return air duct adapters have been included for installer

convenience. They should be used to connect the upstream
side of the air purifier cabinet to the return air duct (see Fig.

7).

g. Install foam tape between the furnace and the air purifier

cabinet.

h. Mounting holes are provided for ductwork and furnace at-

tachment.

Note: Slip
S-cleats onto flanges
on air return duct side.

A05277

Fig. 7 -- Use of Return Duct Adapters

UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
Mounting holes are provided for duct work and furnace

attachment. The screws on the down--stream side of the

cabinet should be installed so that the screw heads are inside

air purifier cabinet to prevent damage to the air purifier

cartridge.

CAUTION

!

i. Seal seams with tape or caulking after the Infinity Air Puri-

fier cabinet has been secured.

Special consideration must be given when applying the 2025 Air

Purifier to a 24 1/2--in (622 mm) wide furnace.

a. Prepare transition, following recommended transition draw-

ing (see Fig. 8). Fabricate a 2 1/4--in (57 mm) tall (minim-
um) transition.

b. Place transition on top of Air Purifier. Secure with sheet

metal screws. Place furnace on top of transition. Make sure
furnace rests evenly on top of transition and Air Purifier.

c. Secure furnace to transition using sheet metal screws. See

Fig. 4.

d. Continue with normal installation practices.

A

(Inside Opening)

Air Purifier Outlet

Front Bracket

Rear Bracket

Furnace Casing Width 24 1/2” (622)

Side Bracket

Side Bracket

NOTE: Weld 3 places
in 4 corners

2 1/4” (57)

24” (610)
(Outside)

5/8” (16)
Flanges
(Where Shown)

B

19 1/2” (495)

A09001

Fig. 8 -- Recommended Transition

GAP

A

A

Advertising