6

Sample Furnace Circuit Board

Power Cord
to EAC Terminals

Use cable connector to secure

power cord to cabinet

Power Supply Connector

Power Supply

Use wire ties to secure power cord

to power supply enclosure

LHT
OFF
DLY

ON

OFF

W2

BL W

EAC-1 TERMINAL

Y1

DHUM

G

COM

24V

W

W

1
Y/Y2

R

TEST/TWIN

HUM

1 2 3

PL
T

A

CRDJ

0.5-AMP024 V AC

FUSE 3-AMP

SEC-1

SEC-2

PL1

NEUTRAL-L2

1

EA C-2

BHT/CLR

BHI/LOR

PL3 1

BL WR

COOL

SP ARE-1

SP ARE-2

1-AMP@115 V AC

EA C-1

PR-1

IDR

HSIR

IDM

IHI/L

O

R

PL2

1

HSI HI LO

S TATU

S

C

OD

EL

E

D

EAC-2 TERMINAL

HI HEA

T

LO HEA

T

L1

Use terminals to connect the

power cord wires to the furnace

EAC-1 & 2, & ground terminals

Power Supply Connector

Power Cord

Alternate Power Cord
Pass-Thru Hole

A06030

Fig. 9 -- Infinity Air Purifier Electrical Connections

Wiring

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off main

power to system. There may be more than 1 disconnect

switch.

!

WARNING

EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
This unit cannot be powered directly from blower motor

leads. Voltages can exceed 190 VAC (120v motors). Do not

wire directly to blower motor. Wiring to blower motor will

damage power supply and void warranty.

CAUTION

!

a. Ensure power has been removed from the heating and cool-

ing system.

b. Turn the Infinity Air Purifier power switch off.

c. Connect the power cord to the power supply connector (see

Fig. 9).

d. Route the power cord through nearest cabinet hole and pro-

tect with enclosed cable connector. Zip ties have been en-
closed to secure the power cord to the side of the power
supply.

e. Attach the quick connect terminals to the furnace EAC--1

and EAC--2 spade connections. Attach the ground ring to

furnace chassis ground.

NOTE: The Infinity Air Purifier is to be powered by 115v/60 Hz.
NOTE: The Infinity Air Purifier should only be powered when
airflow is present. The furnace control EAC spade connections
provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative airflow sensing
mechanism must be used to ensure the Infinity Air Purifier is only
powered when airflow is present. Contact a local Carrier distributor
for information on approved alternatives.

UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Black Lead -- Connect to HOT (L1) or EAC--1 when

provided.

White Lead -- Connect to Neutral (L2) or EAC--2 when

provided.

Green/Ground Lead -- Connect to Appliance Ground

(Chassis).

CAUTION

!

START--UP AND OPERATION

Checking Air Purifier Operation

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

a. Attach the Infinity Air Purifier door to the cabinet. A mag-

net in the door is used to activate a safety switch in the pow-
er supply when the door is installed. The power supply will

not energize the air purifier unless the safety switch is acti-
vated.

CARBON MONOXIDE HAZARD
Failure to follow this warning could result in personal injury

or death.
Do not remove door during blower operation or operate

blower with door removed or improperly latched.

!

WARNING

b. Turn the HVAC system power on and adjust the thermostat

or Infinity System Control to activate the system fan.

c. Turn the Infinity Air Purifier power switch to on position.

GAP

A

A