Caution, Warning, Troubleshooting – Carrier INFINITY 1625 User Manual

Page 8

Advertising
background image

8

natural bristle) or vacuum cleaner with brush attachment. See Fig.
11.
Gently stroke the ionization pins on the top plane of each bar with

enough brush depth to hit front and back tips of the points in the

ionization array. Use a gentle back and forth brushing motion to
clean any small accumulations from the tips of the points. If

desired, use vacuum cleaner with brush attachment to gently
vacuum the frame and components of enhancement module. Also,

vacuum the safety screen to remove accumulated dust and debris.

Reinstall the Safety Screen. Do not operate the unit without the

Safety Screen
Slide in enhancement module.
Reconnect power cord.
Replace the Infinity Air Purifier door.
Turn the Infinity Air Purifier switch to the on position.
Turn heating and cooling system power on.

30°

POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.

Tip of point with residue

Tip of point after cleaning

A06671

Fig. 11 -- Removal of Deposits from Ionization Pins

TROUBLESHOOTING

SAFETY HAZARD
Failure to follow this caution may result in personal injury or

equipment damage.
The following instructions are for use by qualified personnel

only.

CAUTION

!

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
The following procedures will expose electrical components.

Disconnect power between checks and proceed carefully. Only

a trained, experienced service person should install and/or

troubleshoot the Infinity Air Purifier.

!

WARNING

The Infinity Air Purifier is equipped with a power indicator light
located on the door (see Fig. 10). This power indicator light will

illuminate when the Infinity Air Purifier door is installed, the
power switch is in the on position, AND the furnace blower is

running. If the power indicator light is not illuminated, follow the

troubleshooting steps below.
See Table 1.

GAP

A

A

Advertising