Warning – Carrier INFINITY 1625 User Manual

Page 7

Advertising
background image

7

d. The power indicator light above the Air Purifier power

switch should illuminate (see Fig. 10).

e. Check to ensure the light goes off when the Infinity Air

Purifier power switch is set to off, when the blower goes off,
or when the HVAC system power is turned off.

Infinity Control

When the Infinity Air Purifier is used with an Infinity Control, the
Infinity Control can be configured to remind the homeowner when

it is time to change the Infinity Air Purifier cartridge. This

maintenance reminder can be based on either the TrueSenset dirty
filter algorithm or time. The installer should use their discretion to

select the most appropriate option based on the initial system static
pressure.

Maximizing Performance

Maximum air purification performance is obtained when the

furnace blower is set for continuous operation on the thermostat or
Infinity Control.

MAINTENANCE

The Infinity Air Purifier is designed to require minimal

maintenance. Maintenance is limited to the periodic replacement of
the air purification cartridge and inspection/brush cleaning of the

ionization array. Frequency of air purifier cartridge replacement
and cleaning of the ionization array may vary depending on

ductwork design and local environmental conditions, generally

8--12 months.

FIRE HAZARD
Failure to follow this warning could result in personal injury

or equipment damage.
Use of non--factory approved filter cartridge will void the

warranty and may cause damage due to fire.

!

WARNING

To replace the air purifier cartridge, complete the

following steps:

Turn the heating and cooling system power

off.

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Turn the Infinity Air Purifier switch to the off position.
Remove the Infinity Air Purifier door.
Slide out the old air purifier cartridge and discard.
Install the new air purifier cartridge. Make sure the power cord is

flexed out of the way to avoid damage to the air purifier cartridge

pleats during insertion.
NOTE: Verify that the air purifier cartridge is installed correctly.
Make sure that the arrows on the air purifier cartridge point toward
the furnace. This should be in the same direction as airflow and
match the arrows on the sticker inside the cabinet.
Replace the Infinity Air Purifier door.
Turn the Infinity Air Purifier switch to the on position.
Turn heating and cooling system power on.

CARBON MONOXIDE HAZARD
Failure to follow this warning could result in personal injury

or death.
Do not remove door during blower operation or operate

blower with door removed or improperly latched.

!

WARNING

Power Indicator

A06052

Fig. 10 -- Power Indicator

At the time of air purifier cartridge replacement, if a powdery

residue is noticed on the tips of the points in the ionization array,
proceed to clean them by completing the following steps.

Turn heating and cooling system power off.

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Turn the Infinity Air Purifier switch to the off position.
Remove the Infinity Air Purifier door.
Unplug the power cord from the enhancement module.
Slide out the enhancement module assembly and safety screen.

CUT HAZARD
Failure to follow this warning could result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

!

WARNING

Slide out the Safety Screen and set aside.
NOTE: Best cleaning tools: 5--in (127 mm) handle paint brush
with 2--in (51 mm) width (or greater) brush point (synthetic or

GAP

A

A

Advertising