10. In some cases, the bracket has failed at the weld shown in Figure 34. It is recommended

that all sprayers with roll control add weld to the existing bracket to prevent failure. Some
sprayers from 2005 and newer already have gussets added at the factory.

Figure 34: Roll Cylinder Mount Weld Locations

11. Install the 6MB-4MOR (F12) fittings into the cylinder.

12. Install the 4MOR-4FORX90 (F14) fitting onto the cylinder fitting at the cap end of the

cylinder.

Figure 35: Roll Cylinder Installed with Hoses