VENT GRAPH (cont'd)

Note: Maximum propane horizontal vent run is 13' (3960mm) when the vertical vent rise is 10' (3048mm)
Note: Minimum vertical rise is 2' (908 mm)
Note: Minimum horizontal run is 11" (279mm) on a vertical to horizontal installation.

Note: Minimum wall thickness 4" (100mm)
Note: Maximum wall thickness 20" (508mm).

FIGURE 19: BAYVUE DV VENT GRAPHS, MODEL DV 30













































A vent shall not terminate:
A.

Within six feet (1.8 meters) of a mechanical air supply inlet to a building.

B.

Above a utility meter within three feet (1 meter) horizontally of its vertical center line.

C.

Within six feet (1.8 meters) of any gas service regulator vent outlet.