SIT 820 NOVA mV GAS CONTROL VALVE

The 820 Gas Control Valve is shown below in FIGURE 27.
1.

The left knob controls the ON/PILOT/OFF functions.

2.

The right knob controls the manifold pressure to the burners and is labeled HI/LO.

3.

There is a PILOT ADJSUT screw that should only be adjusted by a certified technician.

4.

The SIT 820 has an input pressure test port labeled IN.

5.

The SIT 820 has an output pressure test port labeled OUT.

To use either of the pressure test ports to measure pressure requires test equipment and knowledge required
by a certified service technician. Improperly adjusting the pilot adjust or the manifold pressure can cause
damage to the SIT 820 control valve and should only be accomplished by a certified professional. For
lighting instructions refer to the section on first fire in this manual or on the units control panel.

ON

OFF

PILOT

HI

LO

PILOT

ADJ

IN

OUT

FIGURE 27: SIT 820 mV NOVA GAS VALVE

NOTE: TP stands for thermopile, TH for thermostat, and TP TH for thermopile and thermostat. See
FIGURE 28.

ON/OFF SWITCH

OPTIONAL (millivolt)
REMOTE RECEIVER

OPTIONAL (millivolt)
REMOTE SENDER

OPTIONAL (millivolt)
THERMOSTAT

THERMOSTAT
TERMINAL BLOCK

TP TH

PILOT BURNER

THERMOPILE

ON

OFF

PIEZOELECTRIC
IGNITER

SIT 820 mV CONTROL VALVE

IN

OUT

ON

PI

L

O

T

OFF

HI

LO

ADJ

PILOT

TP

TH

THERMOCOUPLE

IGNITER

1/16" to 1/8"

FIGURE 28: SIT 820 mV NOVA GAS VALVE WIRING DIAGRAM