Trouble shooting guide – Country Flame Bayvue DV 30 User Manual

Page 43

Advertising
background image

Version 1.0h

42

TROUBLE SHOOTING GUIDE

SYMPTOM PROBLEM CORRECTIVE

ACTION

No spark at the pilot burner

Check that the wire is connected to the
push button igniter.
Check if the push button igniter needs
tightening.
Replace pilot assembly if ceramic
insulator is cracked or broken.

Spark gap is incorrect

Spark gap should be 1/16" to 1/8"
from the electrode tip and the pilot
burner. Light the pilot with a match
and adjust the electrode tip to the
required spark gap and proper
location.

Pilot will not light

No gas at the pilot burner

Check that the manual valve(s) is
(are) turned on.
Check the pilot orifice for
blockage.
Replace the valve.
Call the gas distributor.

Out of Propane

Fill the tank

Pilot goes out when
the gas knob is
released

System is not correctly purged
Out of Propane gas
Pilot flame is not large enough
Pilot flame is not engulfing the
generator (thermocouple)

Thermocouple shorting
Faulty valve
Faulty thermocouple

Purge the gas line.
Fill the tank.
Turn up the pilot flame.
Gently twist the pilot head to
improve the flame pattern around
the generator (thermocouple).
Clean the thermocouple.
Replace valve.
Replace thermocouple.

Pilot burning: no
gas to main burner;
gas knob “on”

Main burner is plugged

Remove stoppage in the orifice.

Main burner goes
out; pilot stays on

Pilot flame is not large enough or
not engulfing the thermocouple

Turn the pilot flame. Gently twist
the pilot head to improve the flame
pattern around the thermocouple.

Thermocouple
Shorting

Clean thermocouple and valve
terminals

Check that the thermocouple
insulation is not frayed and
grounding out on the fireplace
housing or burner support.

Burner Flame
yellow and lazy

Dirt in the burner orifice
Wrong orifice
Clogged flue
Improper gas pressure

Remove and clean.
Replace orifice.
Clean flue.
Adjust regulator.