Form I-EEDU, P/N 150492 R6, Page 31

FIGURE 29 - Discharge

Air End of the Heat

Exchanger showing the

Baffle Assembly to be

Removed

Conversion is complete for Sizes 75-100; skip to Step 4.

3. Sizes 125-400 only - Remove the Side Finger Baffles – Refer to FIGURE

30 showing the entering air side of the heat exchanger (baffles shown

in FIGURE 29 have already been removed). Identify the side finger baffles.

Remove both side baffles; each baffle is attached with two screws.

Remove the support

bracket screws and slide

the baffle assembly out

of the heat exchanger.

Replace the screws to

plug the holes.

Baffles (Remove

with the supports

as an assembly.)

Conversion is complete for Sizes 125-400; continue to Step 4.

4. Select a location adjacent to the rating plate for the conversion label. Being sure

the surface is clean and dry, adhere the conversion label that was completed in

Step 1.

Test for proper operation. Be sure to comply with the air throughputs in the table on

page 30.

FIGURE 30 - Entering

Air End of the Heat

Exchanger showing the

Side Finger Baffles to

be Removed

Remove the two

screws from each

of the side finger

baffles. Remove both

baffles.

Heat exchanger side

finger baffles being

removed (Sizes 125-

400).

NOTE: Do NOT remove

these side finger baffles

on Size 75 and 100.