0 dimensions and clearances, 0 receiving, moving, and uncrating (cont’d), 1 dimensions – Reznor ZQYRA Unit Installation Manual User Manual

Page 4: 3 uncrating and preparation, 2 storage and moving (cont’d), Figure 1 - dimensions - inches (mm)

Advertising
background image

Form I-ZQYRA P/N 260414R5, Page 4

4.0 Dimensions and Clearances

4.1 Dimensions

Dimensions - inches and mm

Size

A

B

C

D

E

F

G

H

J

K

8

inches

9-1/4 14-5/16 32-15/16 24 39-1/2 9-3/4 6-1/4 34-7/8 27-3/8 22-3/8

mm

235

364

837

610 1003

248

159

886

695

568

12

inches

12-1/4 21-3/8 36-5/16 30 45-1/2 12-3/4 9-1/4 37-7/8 30-3/8 25-3/8

mm

311

543

922

762 1156

324

235

962

772

645

FIGURE 1 - Dimensions - inches (mm)

3.3 Uncrating and

Preparation

Immediately upon uncrating, check the electrical characteristics to verify that the unit

is suitable for the installation site.
Shipped-with and Shipped-separate Items - A carton shipped inside the unit con-

tains the vertical supply air opening cover and parts to assemble and install the inlet

and exhaust hoods. The hoods will be attached after the unit is in the installed loca-

tion.
Before beginning installation, be sure that all shipped-separate options ordered are

available at the site. Shipped-separate options could include a roof curb, a wall-

mounted control, and/or a disconnect switch.
Supply Air (Discharge) and Return Air Openings - To enable the installer to adapt

to either vertical or horizontal ductwork, the cabinet has both vertical and horizontal

supply and return air openings. Both the horizontal supply air and return air openings

are capped during shipping.
NOTE: There are no vertical duct connections on the unit; duct flange connections are

part of the roof curb. The curb is designed to slide the ductwork into the vertical duct

openings from the roof before the unit is lifted to the curb.

* Configuration of

Supply (Discharge)

Air and Return Air

Ductwork can be either

Vertical or Horizontal

Follow the instructions in

Paragraph 6.2 that apply.
NOTE: Vertical duct

connections are on the roof

curb. There are no vertical

duct flanges on the unit.

The curb is designed for

ductwork to be installed

from the top before the unit

is set on the curb.

A

24

(610)

Exhaust

Air

Opening

15-3/8

(391)

Inlet Air

Filter

Access

Panel

REAR VIEW

(Exhaust End)

3-3/8

(86)

3-3/8

(86)

19-1/2

(495)

Inlet Air

Opening

Exhaust

Hood

B

27 (686)

Wheel

Access

Panel

Supp

ly

Fan Access Panel

Inlet

Side

Post

Cover

3/4” SCH 40

Condensate Drain

Socket Adapter Fitting

22-1/8

(562)

3-7/8

(98)

70-1/2 (1791)

C

D

E

*Horizontal

(Discharge)

Supply Air

Opening

*Horizontal Return Air

22

(559)

9

(229)

14-1/4

(362)

15 (381)

7-9/16

(141)

15

(381)

F

G

Electrical

Compartment

- Controls

and

Compressors

Return Air

Filter

Access Panel

H

K

J

Non-fused

Optional

Disconnect

Switch

High Voltage Entrance

Low Voltage Entrance

3

(76)

52-11/32

(1330)

(lifting hole

centerline)

64-1/2 (1638)

(lifting lug centerline)

Exhaust

Hood

24-1/2

(622)

6-1/2 (165)

Inlet Hood

22-15/16

(583)

10

(254)

22 (559)

14-3/8 (365)

*Vertical Return

Air Opening

*Optional Supp

ly Air

Opening

9 (229)

21

(533)

3-3/8 (86)

3-5/16 (84)

1-1/2 (38)

4 Lifting Holes

CONTROL SIDE

(Partial view)

8-1/2

(216)

20

(508)

50-3/8 (1280)

Inlet Air Hoods

Size 8 - 2 Hoods

Size 12 - 3 Hoods

BOTTOM VIEW

(from underneath)

3-5/16

(84)

SIDE VIEW

(Side Opposite Controls)

FRONT VIEW

(Horizontal Supply and

Return Air Connections)

(Reheat

Pump

Coil)

If the unit is going to be stored, take precautions to prevent condensation inside the

electrical compartment and motors. To prevent damage to the unit, do not store sitting

on the ground.

3.0 Receiving,

Moving, and

Uncrating

(cont’d)

3.2 Storage and Moving (cont’d)

Advertising