Vermont castings gas patio fire, Gpf dimensions, Gas specifications – Vermont Casting GPFMP User Manual

Page 3: Gas inlet pressures, Minimum clearance to combustibles

Advertising
background image

3

Vermont Castings Gas Patio Fire

GPF Dimensions

11

¹⁄₂

"

(292mm)

5"

(127mm)

12"

(305mm)

3

¹⁄₄

"(83mm)

16

¹⁄₄

"

(413mm)

11

³⁄₈

"

(289mm)

8

¹⁄₄

"

(210mm)

Burner

4237

Fig. 1 Physical dimensions.

Burner Assembly

Flex Line

Valve

Propane
Regulator/Hose

Natural
Gas Hose

FP1129

Fig. 2 GPF parts.

Gas Specifications

Max. Input

Model

Fuel

Btu/Hr

GPFMN

Natural Gas

75,000

GPFMP

Propane Gas

65,000

Gas Inlet Pressures

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0”w.c.

14.0” w.c.

Minimum Clearance to Combustibles

Inches

mm

Floor

0

0

Side Walls

16

406

Top of unit to ceiling

7 ft.

2.1m

Advertising